Chariot
Votre panier est vide.

COSEL ADA1000F-24

Electrical Specifications
  • Input Voltage Range: 85 – 264 VAC (Single Phase) or 120 – 350 VDC.
  • Output Voltage: 24 VDC.
  • Output Voltage Adjustment Range: 20.0 to 28.0 VDC.
  • Rated Output Current (Convection): 21.0 A (at 100 VAC) / 25.0 A (at 200 VAC).
  • Rated Output Current (Forced Air): 33.0 A (at 100 VAC) / 42.0 A (at 200 VAC).
  • Peak Output Current (Convection): 42.0 A (at 100 VAC) / 50.0 A (at 200 VAC).
  • Peak Output Current (Forced Air): 63.0 A (at 100 VAC) / 83.0 A (at 200 VAC).
  • Rated Output Power (Convection): 504 W (at 100 VAC) / 600 W (at 200 VAC).
  • Rated Output Power (Forced Air): 792 W (at 100 VAC) / 1008 W (at 200 VAC).
  • Efficiency: 88% to 91% typical depending on input voltage.
Protection and Control Features
  • Overcurrent Protection: Operates above 101% of peak current, intermittent recovery.
  • Overvoltage Protection: Shuts down operating voltage above 115% of nominal rating.
  • Thermal Protection: Shuts down output during sustained overheating conditions.
  • Inrush Current Limiting: Thermistor and relay based circuit integrated.
  • Output Indicator: LED illumination confirms active DC output status.
Environmental and Structural Data
  • Operating Temperature Range: -10°C to +65°C (Derating required over 50°C).
  • Storage Temperature Range: -20°C to +75°C.
  • Operating Humidity: 20% to 90% RH (Non-condensing).
  • Cooling Method: Convection or forced air (External fan required unless -F option ordered).
  • Mounting Type: Chassis mount.
  • Weight: 3.0 kg maximum.
Safety and Compliance
  • Agency Approvals: UL60950-1, C-UL, EN60950-1, EN50178.
  • Conducted Noise: Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B.
  • Harmonic Attenuator: Complies with IEC61000-3-2.

Demander un devis

Translation missing: fr.general.search.loading